Latest Tender Detail from southern railway SR for the tender for transcatheter aortic valve implant set consists of the following in sterile individual pack, (i).transcatheter heart valve - 01 unit it should be made of bovine/porcine pericardium tri leaflet valve , made of medical grade alloy with hybrid cell design . it should have internal/exteranl pet skirting or both. the size of the valve should range from 20 mm to 32 mm or more. (ii).valve delivery system - 01 unit the valve should be crimped or loaded over the delivery system prior to insertion into the patients vasculature. should be 0.035 wire compatible(iii).balloon dilatation catheter - 01 unit balloon size ranges from 16 mm to 25 mm with 30 mm length. the balloon rbp should be minimum 6 atm. (iv).introducer sheath 01 unit should be minimum 14 fr and length of minimum 30 cm ,compatible with all valve sizes. should have haemostatic valve and side port with three way. should be compatible for femoral artery size ranging from 5 mm to 7 mm. (v) inflation device - 02 units (30ml/40ml/60ml) (vi)syringes 50 cc - 02 units the firm should be able to supply any size of valve ,delivery system and balloon suitable for the patient. unit:set, srphc82270310-transcatheter aortic valve implant set consists of the followi ng in sterile individual pack, (i).transcatheter heart valve - 01 unit it should be made of bo vine/porcine pericardium tri leaflet valve , made of medical grade alloy with hybrid cell d esign . it should have internal/exteranl pet skirting or both. the size of the valve should range from 20 mm to 32 mm or more. (ii).valve delivery system - 01 unit the valve should be crimped or loaded over the delivery system prior to insertion into the patients vasculatu re. should be 0.035 wire compatible(iii).balloon dilatation catheter - 01 unit balloon size r anges from 16 mm to 25 mm with 30 mm length. the balloon rbp should be minimum 6 atm. (iv ).introducer sheath 01 unit should be minimum 14 fr and length of minimum 30 cm ,compatib le with all valve sizes. should have haemostatic valve and side port with three way. shoul d be compatible for femoral artery size ranging from 5 mm to 7 mm. (v) inflation device - 02 units (30ml/40ml/60ml) (vi)syringes 50 cc - 02 units the firm should be able to supply any siz e of valve ,delivery system and balloon suitable for the patient. unit:set in perambalur, tamil nadu,. Reference number 16962500. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.