Latest Tender Detail from indian navy for the tender for procurement and installation of ventilation system at ships galley of ins angre supply installation testing and commissioning of 11tr double skin tfa fabricated from , supply installation testing and commissioning of bluestar outdoor 11 tr single crust , supply installation balancing and commissioning of factory , supplying and fixing of 25mm thickness xlpe , supply fabrication and fixing of 11 by 8 inch and 5 by 8 inch , supply and laying of frls type copper power , supply installation and balancing of extruded , supply fabrication and installation of tfa , supply fabrication and installation of odu , supply installation and testing of flexible connections , supply and fixing industrial grade upvc , supply and fixing of powder coated ms enclosure , installation and commissioning of complete , supply installation testing and commissioning of 25tr dx double skin air handling , supply installation testing and commissioning of bluestar outdoor 8.5 tr , supply installation balancing and commissioning of factory fabricated , supply and fixing of 25mm thickness xlpe , supply fabrication and fixing of 11 by 8 inch and 5 by 8 inch sizes , supply fabrications and installation of ahu , installation and commissioning of complete system, procurement and installation of ventilation system at ships galley of ins angre, supply installation testing and commissioning of 11tr double skin tfa fabricated from outer skin with zero point 60 mm thick precoated gi sheet and plain zero point 60 mm thick inner gi sheet with 25 mm thick injected puf insulation with aluminum extruded frame work having thermal break profile with internal coving complete with mixing box backward centrifugal fan copper cooling coil and filter section complete with pre filters designed to remove particles down to 10 microns with an efficiency of 90 percent on ashrae std 52 to 56 and 90 percent on bs 2831 test dust no 2 junior filter in crca construction duly powder coated the filter shall have 3 stage of non woven synthetic polymedia sandwitched between 2 layers of hdpe mesh duly epoxy sealed at the ends, supply installation testing and commissioning of bluestar outdoor 11 tr single circuit r410 compatiable to the above tfa, supply installation balancing and commissioning of factory fabricated gss sheet metal rectangular as per smacna standards and specifications complete with neoprene rubber gaskets elbows splitter vanes hangers etc as per approved drawings and specifications all supports should be made of galvanised steel angle with drilled holes and gi threaded rods with check nuts and washers of hilti with support from roof, supplying and fixing of 25mm thickness xlpe with aluminium foil class o insulation on duct after applying manufacturers recommended adhesive density of the material shall be 25 to 30 kg per m3 the insulation material shall be fire rated the joints shall be sealed with 50 mm wide and 3 mm thick self adhesive tape insulation complete as per specifications and as required, supply fabrication and fixing of 1 1 by 8 inch and 5 by 8 inch sizes copper piping along with inline fittings insulation sleeve and support, supply and laying of frls type copper power cable 4 core 4 sqmm between electrical panel iud and odus, supply installation and balancing of extruded aluminium construction linear grill with opposed blade collar dampers for supply or return air the grill shall be powder coated off white with standard finish ral 9016 and installed as per approved shop drawings and specifications, supply fabrication installation of tfa ms platform with ms c channel ms chukker plate and fixing with anchor fastener, supply fabrication and installation of odu ms platform with ms l angle and fixing with anchor fastener, supply installation and testing of flexible connections shall be constructed of fire resistant double canvas fire retardant fabric made up of vinyl polyster fabric with minimum 150 mm secured to galvanized sheet metal on either side, supply fixing industrial grade upvc drain pipe with 9 mm thick nitrile rubber insulation upvc pipe, supply and fixing of powder coated ms enclosure ip rated electrical control panel ip54 by ip55 compatible with building management systems bms for centralized monitoring and control equipped with mcb mccb overload relays phase failure protection and short circuit protection, installation and commisssioning of complete system along with flushing vaccumising and gas charging with suitable refrigerant if required, supply installation testing and commissioning of 25tr double skin air handling units fabricated from outer skin with zero point 60 mm thick precoated gi sheet and plain zero point 60 mm thick inner g i sheet with 25 mm thick injected puf insulation with aluminum extruded frame work having thermal break profile with internal coving complete with backward centrifugal fan copper cooling coil and filter section complete with pre filters designed to remove particles down to 10 microns with an efficiency of 90 percent on ashrae std 52 to 56 and 90 percent on bs 2831 test dust no 2 junior filter in crca construction duly powder coated the filter shall have 3 stage of non woven synthetic polymedia sandwitched between 2 layers of hdpe mesh duly epoxy sealed at the ends, supply installation testing and commissioning of bluestar outdoor 8 point 5 tr single circuit r410 compatiable to the above ahu, supply and laying of frls type copper power cable 4 core 4 sqmm between electrical panel iud odus, supply installation and balancing of extruded aluminium construction linear grill with opposed blade collar dampers for supply return air the grill shall be powder coated off white with standard finish ral 9016 and installed as per approved shop drawings and specifications, supply fabrication and installation of ahu ms platform with ms c channel ms chukker plate and fixing with anchor fastener, supply and fixing industrial grade upvc drain pipe with 9 mm thick nitrile rubber insulation upvc pipe, supply and fixing of powder coated ms enclosure ip rated electrical control panel ip54 or ip55 compatible with building management systems bms for centralized monitoring and control equipped with mcb mccb overload relays phase failure protection and short circuit protection, installation and commissioning of complete system along with flushing vaccum and gas charging with suitable refrigerant if required in mumbai, maharashtra,. Reference number 16500334. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.