Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

15Latest Galvanised foundation bolt including nuts and washers Tenders List

Latest Galvanised foundation bolt including nuts and washers Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Galvanised foundation bolt including nuts and washers tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Galvanised foundation bolt including nuts and washers tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Galvanised foundation bolt including nuts and washers Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Galvanised foundation bolt including nuts and washers tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Galvanised foundation bolt including nuts and washers Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Galvanised foundation bolt including nuts and washers Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Galvanised foundation bolt including nuts and washers Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Galvanised foundation bolt including nuts and washers tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Galvanised foundation bolt including nuts and washers Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Galvanised foundation bolt including nuts and washers sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Galvanised foundation bolt including nuts and washers tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Galvanised foundation bolt including nuts and washers tenders.

Is EMD mandatory for all Galvanised foundation bolt including nuts and washers tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Galvanised foundation bolt including nuts and washers work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Galvanised foundation bolt including nuts and washers tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Galvanised foundation bolt including nuts and washers Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 16990706
Source : GEM Tenders
LIVE TENDER
T18 Ref No : 16766496
Location : jammu , jammu & kashmir
Source : GEM Tenders
tender for supply and fixing steel tubler swaged pole , material and labour plain cement concrete , material and labour pcc , cross arms bracings supports clamps , pin type porcelain vitreous white brown , disc type insulator porcelain vitreous , acsr conductor of size mink complete , material and labour for earth continuity , excavating in trenches in hard dense , removing excavated material to a distance , returing filling in including spreading levelling, repair and maintenance of electrical poles and overhead conductor ops loc, supply and fixing steel tubler swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified type 410 sp31 09 mtr long and duly painted with two coats anticirrosive paint internally upto planting depth alternate black and yellow straps of synthetic enamel paint 30 cm each upto 1.5 mtr from ground level and remaining pole with aluminium paint including wiring all as specified by engineer in charge., material and labour plain cement concrete 1 ratio 4 ratio 8 type d2 using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed., material and labour pcc 1 ratio 3 ratio 6 type c1 using 20 mm graded stone aggregate for coping of poles road plinth blocks of lt poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and directed., cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint all as specified., pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150mm height 150mm dia for 11000 volts grade complete., disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volt complete., acsr conductor of size mink complete 1200rm x 3 run equal 1.8km at the rate 255 kg equal 918 plus 3 percentage sag 27.54 equal 945.54 kg equal 9.45 qtl, material and labour for earth continuity conductor or main earthing lead using 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down old wire complete, excavating in trenches in hard dense soft soil n exc 1.5 m wide and n exc 1.5 m in depth for foundation of poles trenches for laying of cable or for shafts wells cesspits manholes pier holes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed., removing excavated material to a distance not exceeding 50 mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point., returing filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm each all as required and directed.
T18 Ref No : 16640089
Location : jammu , jammu & kashmir
Source : GEM Tenders
tender for supply laying testing and commissioning ug cable xlpe , material and labour for cable jointing kit end joint , excavating in trenches in hard dense soft soil , removing excavated material to a distance , returing filling in including spreading , supply and laying of dwc double wall , material and labour for cutting through , supply and fixing gi tubing medium grade , material and labour for earthing complete , supply and fixing in replacement mccb , supply and fixing change over switchs , material and labour for three phase aluminum, repair and maintenance of aluminum cable and including connected items at charlie hill ops location, supply laying testing and commissioning ug cable xlpe insulated screened pvc bedded galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core including taking down old cable with suitable thimbles from trench complete. make polycab paragon gloster, material and labour for cable jointing kit end joint for 1.1 kv earthed grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core xlpe armoured aluminium conductor cable of size 70 sqmm to 95 sqmm., excavating in trenches in hard dense soft soil n exc 1.5 m wide and n exc 1.5 m in depth for foundation of poles trenches for laying of cable or for shafts wells cesspits manholes pier holes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed., removing excavated material to a distance not exceeding 50 mtr and deposting where directed at a level not exc 1.5 mtr above the starting point, returing filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm each all as required and directed., supply and laying of dwc double wall corrugated hdpe pipe isi marked is 16205 part-ii of outer dia of 93 mm and inner dia 80 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler o ring etc for protection cable complete all as specified and as directed. make rex polyextrusion genimi, material and labour for cutting through existing road surfaces pcc pcc tiles etc and making trench rm of minimum 500mm wide 100cm in depth along the cross section of road for laying of pipes or ug cables including returning filing in well ramming and removal of surplus soil to a distance not exc. 50 mtrs and repairs to road surfaces to match with existing specification after laying the pipes cable etc. all as specified and directed, supply and fixing gi tubing medium grade tubes 80 mm bore including taking down old unsv one complete all as specified and directed., material and labour for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below gl with top edge of the plate not less than 1.5 mtr below normal gl and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron 4mm dia wire by means of bolts nuts check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to db and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore gi light grade with funnel and wire mesh including all necessary excavation and earth work pcc chamber in cement concrete 1 ratio 3 ratio 6 type c2 and rcc cover and all as shown in electrical plate no 3 of mes schedule pt i of 2009., supply and fixing in replacement mccb tpn 100 amps 415 volts complete incl taking down old unserviceable make legrand havells l and t indoasian hpl, supply and fixing change over switchs on load 63 amps 4 pole including taking down old unsv one complete all as specified and directed., material and labour for three phase aluminum rectangle bus bar box 4 way of 150 amps rating complete all as specified and as directed

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16121822
Location : bardhaman , west bengal
Source : GEM Tenders
tender for supply laying testing and connecting xlpe sheathed pvc insulated screened pvc size 3.5 core 240 sqmm complete all as specified and as directed. , supply installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy sound level not more than 75db , m and l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground earth pit not less than 2.25mtr , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in soft loose soil complete all as specified and as directed. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified and as directed. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil complete all as specified and as directed. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches of 230mm , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable complete all as specified and as directed. , s and f galvanised iron pipe 80mm bore dia light grade for protection of ug cable laid in floors road crossing , s and f hdpe dwc double walled corrugated of diameter 90 mm including disconnection and connection of cable , material and labour for manufacturing installation testing and commissioning of factory made and tested cpri approved amf , m and l for surface excavation n.exc not exceeding 30 cm deep and averaging 15cm deep , m and l for hardcore using broken stone or boulders of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick , m and l for cement concrete in foundations filling and mass concrete type d2 1 4 8 , m and l for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping for pole inclduing form work , m and l for excavating in post holes or similar holes each n exc 0.5 cu. m getting out returning filling in and ramming earth , s and f for steel work in tubular trusses cloumn purlin including special shaped washer nut bolt etc. , s and f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick , m and l for preparation of steel surfaces of any description over 10 cm , m and l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 , providing and laying at or near ground level factory made kerb stone of m25 grade , m and l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm , s and f 4pole 630 amp changeover switch with enclosure suitable for 415 v ac 3phase 4 wire , wrecking crow bar or claw bar as per is 706 (q3), supply, laying, testing and connecting xlpe sheathed,pvc insulated screened pvc bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 240 sqmm complete all as specified and as directed., supply, installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy (sound level not more than 75db at a distance of 1 mtr) 14 guage as per guidelines issued by central pollution control board (cpcb ivplus, 4plus), 415 volts, 3 phase, 50 hz supply complete, control panel suitable for giving an output of 250 kva and alternator of suitable capacity and rpm coupled with each other with flexible coupling mounted on anti vibration pads on foundation as recommended by manufacturer. the dg set shall comprise of self starter with batteries, turbocharger, water cooler and comprising all standard fittings, fixtures & all piping etc. as below (a) alternator directly coupled with engine and suitable to produce 415 volts, 3 phase, 4 wire system, 50 hz, 0.8 pf 1500 rpm of capacity 250 kva all as per is 13364 and upto date amendments with h class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball / roller bearing with damper winding in each pole, complete all as specified and directed. (b) engine water cooled diesel engine (cpcb norms iv compliance) developing 105 bhp having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per oem) as per is 10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 rpm industrial type as per bs 649 or is 1601 with ai electronic governor suitable to regulate speed of dg set from no load to full load complete with fuel tank of capacity as per manufacturer s recommendation, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer muffiers etc. for continuous operation and standard accessories, sump pre heaters, cold start kit etc., m&l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground, earth pit not less than 2.25mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the galvanised iron strip of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by provision of 40mm bore gi pipe medium grade and including provision of concrete pit in pcc 1 2 4 type b 1 (using 20mm grade crushed stone aggregate) with 40mm thcik rcc (type b 1) cover reinforced with 8mm dia tmt bar both ways with 12mm dia round bar handle and frame of angle iron 25x25x3mm with lugs 02 nos and 20mm bore gi light grade watering pipe with funnel and wiremesh and filling common salt and charcol and test point with fixing arrangements and including necessary excavation in any type of soil, returning filling in and removing excavated soil to a distance of 50mtr from the site, complete all as shown on electrical plate no 3 of mes ssr part i and directed., excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in soft / loose soil, complete all as specified and as directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed., removing excavated materials (soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil, complete all as specified and as directed., m&l sand cushioning (dry) in trenches for protection of ug cables (below, above and around the ug cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (note for the purpose of payment, punned thickness of sand cushioning only shall be measured and paid)., m&l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable, complete all as specified and as directed., s&f galvanised iron pipe 80mm bore (dia) light grade for protection of ug cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and as directed., s & f hdpe dwc (double walled corrugated) of diameter 90 mm including disconnection and connection of cable near panel/oh for pipe fixing including joints complete all as directed., material and labour for manufacturing, installation testing and commissioning of factory made and tested, cpri approved amf panel for 250 kva dg set, indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 volts, 3 phase 4 wire 50hz ac supply system, conforming to is 5039, ip54 class protection and made of 3mm crca mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated al. bus bar 1000 amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for mccb with suitable capacity of al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments including necessary pcc in 1 2 4 type b1 using 20mm graded stone aggregate for platform of suitable size , prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following acessories incomer1 & 2 (main & dg) (a) busbars 1000a tpn 415volts 3phase 4 wire color coaded aluminium busbars 1 lot (b) mccb 630a fp edo 50ka microprocessor based ( o/c, s/c & e/f) release with motor, closing & shunt, aux. contact 4noplus4nc 2 nos. (c) amf relay (econ) 1 nos. (i) digital ammeter 1 nos. (ii) digital voltmeter 1 nos. (iii) ct 1000/5a cl1 10va 1 nos (iv) phase indication light red 230v ac 1 nos. (v) phase indication light yellow 230v ac 1 nos. (vi) phase indication light blue 230v ac 1 nos. (vii) indication lamp 22mm dia color red 240v ac (on) 2 nos. (viii) indication lamp 22mm dia color green 240v ac (off) 2 nos. (ix) indication lamp 22mm dia color amber 240v ac (trip) 2 nos. etc., m&l for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed., m&l for hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, all as specified and as directed., m&l for cement concrete in foundations, filling and mass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., m&l for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed., s & f for steel work in tubular trusses, cloumn, purlin including special shaped washer, nut, bolt etc. complete using erw or induction butt welded tubes conforming to i.s.1161 1979 grade st.240 complete all as specified., s&f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, m & l for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified, m&l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 of 60 mm thickness, m35 grade with grey cement and pigment all as specified and directed., providing and laying at or near ground level factory made kerb stone of m25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1 3 (1 cement 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed., m&l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% water complete all as specified and directed by engrincharge., s&f 4pole, 630 amp changeover switch with enclosure, suitable for 415 v ac, 3phase, 4wire, 50 hz system, for changeover between main supply and dg set. the switch shall be heavyduty, onload type conforming to is/iec 609473, with silver alloy contacts and adequate breaking capacity. the unit shall be mounted on a sturdy angle iron frame fixed over pcc block with necessary nuts, bolts and support structure. terminals shall be suitable for cable/busbar connection and provision for safe manual operation (or motorised operation, if required) shall be included complete with all accessories, mounting hardware all as specified and directed.
T18 Ref No : 16213419
Location : jammu , jammu & kashmir
Source : GEM Tenders
corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of
T18 Ref No : 16213423
Location : jammu , jammu & kashmir
Source : GEM Tenders
corrigendum tender for taking out servo voltage stabilizer of capacity , rewinding of dimmer coil various of stabilizer , supply and fixing in replacement of dimmer stat , supply and fixing in replacement sensing control card , supply and fixing in repair servo stabilizer , supply and filling new transformer oil , supply and fix triple pole god mechanically , material and labour for cable jointing kit end joint , filtration dehydration of transformer oil of three phase , supply and fixing in replacement steel tubler swaged poles , material and labour plain cement concrete , material and labour pcc , supply and fixing in repair pin type porcelain , supply and fixing in repair disc type insulator , ng in trenches in hard dense soft soil , removing excavated material to a distance not exceeding , returing filling in including spreading levelling watering, repair and maintenance of servo voltage stabilizer and miscellaneous items, taking out servo voltage stabilizer of capacity 180 kva 3 phase 4 wire 440 v ac supply for unbalanced balanced load oil cooled from foundation after disconnecting all electrical connections etc. dismentling for pre inspection by lifting of assembly and repairing replacement of worn out parts and testing after re installatio on same foundation., rewinding of dimmer coil various of stabilizer of any capacity with super enamelled copper winding wire of appropriate gauge as per existing pattern alongwith insulating material and made the surface for suitable contact with carbon bush complete after removing existing burnt winding wire and cleaing complete all as spd and directed., supply and fixing in replacement of dimmer stat 75 amps oil cooled single phase, supply and fixing in replacement sensing control card pcb to control the voltage variation at upper and lower limit complete, supply and fixing in repair servo stabilizer relay 150 to 200 amp complete., supply and filling new transformer oil in voltage stabilizer for topping up level or for replacement of unfit oil. dielectric strength should not be less than 45 kv., supply and fix triple pole god mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 amps suitable for 11 kv including taking out old god complete., material and labour for cable jointing kit end joint for 11 kv earthed grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 300 sqmm., filtration dehydration of transformer oil of three phase servo voltage stabilizer and step down transformer 11 0.433 kv for increasing dielectric strength not less than 45 kv., supply and fixing in replacement steel tubler swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified type 410 sp31 09 mtr long and duly painted with two coats anticirrosive paint internally upto planting depth alternate black and yellow straps of synthetic enamel paint 30 cm each upto 1.5 mtr from ground level and remaining pole with aluminium paint including wiring complete., material and labour plain cement concrete 1 ratio 4 ratio 8 type d2 using 40mm graded stone aggregate for foundation of poles., material and labour pcc 1 ratio 3 ratio 6 type c1 using 20 mm graded stone aggregate for coping of poles road plinth blocks of lt poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete., supply and fixing in repair pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150mm height 150mm dia for 11000 volts grade complete., supply and fixing in repair disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volt complete., excavating in trenches in hard dense soft soil n exc 1.5 m wide and n exc 1.5 m in depth for foundation of poles trenches for laying of cable or for shafts wells cesspits manholes pier holes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete., removing excavated material to a distance not exceeding 50 mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point., returing filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm each all as required and directed.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16174784
Location : jammu , jammu & kashmir
Source : GEM Tenders
corrigendum tender for rewind of submersible motor 7.5 hp , sub cable 4 sqmm 3 core complete. , gm bearing bush , water seal , cable seal , revolving disc , sand guard , dol bush , dol sleave , ss distance sleeve , rottar sleeve turning and grinding , coupling key , impellar key , t nut , guide bush , gm neck ring , nut bolts with washer , rubber packing flange of size 150 mm , cable jointing kit , painting of submersible pump set , ms column pipe 100 mm dia medium grade , labour charges for taking out and relowering , labour charges for opening cutting rewinding , supply installation testing and commissioning , material and labour for making , attending day to day emergency breakdowns , attending day to day emergency breakdowns complaints of damaged , material and labour pcc 1 , supply and fixing rotational moulded , material and labour for disconnecting , supply only anti friction heavy duty , material and labour for removing swt column pipes , material and labour for earthing , supply laying 50 mm bore steel water , supply and fixing in replacement , excavation in trenches not , returning filling in including spreading leveling , removing excavated soil to a distance, repair and replacement to submersible pump set, rewind of submersible motor 7.5 hp, sub cable 4 sqmm 3 core complete., gm bearing bush, water seal, cable seal, revolving disc, sand guard, dol bush, dol sleave, ss distance sleeve, rottar sleeve turning and grinding, coupling key, impellar key, t nut, guide bush, gm neck ring, nut bolts with washer 1 by 2 x 2 inch, rubber packing flange of size 150 mm, cable jointing kit, painting of submersible pump set, ms column pipe 100 mm dia medium grade of 3 mtr in length, labour charges for taking out and relowering the sub pump set from bore well, labour charges for opening cutting rewinding cleaning complete the sub pump for repairing and refixing the same after repairing, assembling testing complete, supply installation testing and commissioning in repairs of sathya sai dosing drum adjustable dozing pump including fixing complete, material and labour for making 100 percentage serviceable to the amf lt panel startor suitable for motors and submersible pump by tracing out defects and replacing unsv parts including control wiring complete. minor parts such as nuts, bolts, washers, thimbles etc shall be deemed to be included in the quoted rate., attending day to day emergency breakdowns complaints of damaged water supply lines of 15 to 25mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled semi skilled man power for smooth functioning of water supply., attending day to day emergency breakdowns complaints of damaged water supply lines of 40mm to 50mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled semi skilled man power for smooth functioning of water supply, attending day to day emergency breakdowns complaints of damaged water supply lines of 80mm to 150mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled semi skilled man power for smooth functioning of water supply, material and labour pcc 1 ration 3 ratio 6 type c1 using 20 mm graded stone aggregate for platform of motor and water storage tank size 1.5 x 1.5 x 0.4m etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete., supply and fixing rotational moulded polyethylene water storage tank inner and out white five layers isi marked cylinderical vertical with closed top hoisted with threaded cap and fixed of capacity 2000 liters each including all accessories including taking down of old broken water tank complete., material and labour for disconnecting and removing the squirrel cage 3 phase 415 volts 50 hz induction motor of 7.5 hp capacity from its foundations by disconnecting electrical connections and motor couplers taking it to workshop for repair and dismantling and opening up of motor removing burnt out winding wires complete cleaning startor and rotor assembly, supply only anti friction heavy duty bearings suitable for 7.5 hp., material and labour for removing swt column pipes upto 100 mm dia with submersible flat cable of any type and dismantling and taking up down submersible pump and motor assembly of capacity 7.5 hp shifting to workshop and removing unserviceable spares replacing with new spares such impeller bushes distance bush seal etc of same specifications type model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets assembling back and testing for proper function including necessary machining works as required bringing back and reinstalling into the swt complete., material and labour for earthing in repalcement complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to and including 25 x 4 mm galvanised earth strip by means of bolts nuts check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical, supply laying 50 mm bore steel water tubing medium grade galvanised with all fittings including short lengths laid in trenches complete with all fittings such as bends elbows tee short pieces connectors back nuts diminishing pieces caps and plugs unions etc including taking down old unsv pipe any type complete, supply and fixing in replacement direct on line starter in sheet metal enclosure for motor rating 415 volts 3 phase 50 hz 9-14 amps relay maximum range of capacity 7.5 hp complete, excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts wells cesspits manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft loose soil complete, returning filling in including spreading leveling watering and well ramming in layer not exceeding 25 cms thick after laying and testing of cable complete, removing excavated soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete
T18 Ref No : 16586319
Location : bardhaman , west bengal
Source : GEM Tenders
corrigendum tender for supply laying and testing cable xlpe insulated screened pvc bedded galvanized steel strip etc. , excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting etc. , excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out etc. , returning filling in including spreading levelling watering and well ramming in layers etc. , removal of surplus soil to a distance not exceeding 50 m and depositing where etc. , supply and lay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm etc. , supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc. , m and l for double wall corrugated dwc high density polyethylene pipes hdpe of 90mm dia etc. , m and l for fixing gi tubing 80mm dia light grade use for the protection of cable etc. , m and l for manual boring under road crossing and laying pipe across the road etc. , sandf pcc cable route marker of size 900x300x70mm embossed with ht ug etc. , material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts etc. , m and l for switch air break gang operated triple pole out door type unit on ht 11 kv etc. , m and l for 11 kv 200 amps outdoor type horn gap fuse set conforming to is 9385 part i and ii etc. , m and l for cross arms bracing supports clamps and back plates fabricated from structural etc. , m and l for pin type porcelain vitreous brown insulator of size 150mm height 150mm etc. , m and l for lightning arrester surge protector 11 kv grade heavy duty single pole etc. , s and f danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white etc. , m and l for cement concrete in foundations filling and mass concrete type d2 etc. , m and l for pcc 1 3 6 type c2 using 40mm grade aggregate as in foundation for pole etc. , m and l for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping for pole etc. , m and l for earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick etc , m and l for earth continuity conductor or main earthing lead fixed to wall on batten etc. , m and l for disc type porcelain polymer insulator vitreous 145 mm height and 255 mm etc. , pick axe as per is 273 (q4), supply, installation, testing of current transformer 33kv, single phase, outdoor oil filled , ratio 150 75/5 5a , two core, one metering (burden 15va, accuracy class 0.5) and one protection core (burden 30va, accuracy class 5p20) insulation level 36 kv / 70 kv as per is 2705 to suit vcb make complete incl taking out old ct all as per sample and directed., supply, installation, testing of 33 kv single phase out door oil cooled pt of ratio 33 kv/ rt 3 / 110 v/rt 3 accuracy class 1.0 . burden 100va. insulation class 70/170 kv , voltage fector 1.2 cont and 1.5 for 30 sec , confirming to is 3156 complete (as per sample) incl taking down old unserviceable pt all as specified and directed., supply & fixing of 33 kv disc type suspension insulator, porcelain/polymer type, 70 kn mechanical strength, complete with cap and pin, ball & socket type coupling, suitable for 33 kv overhead line, conforming to is 731, including all fittings and accessories complete all as specified and directed., supply & fixing of 33 kv post type insulator, porcelain/polymer, brown glazed, suitable for 33 kv overhead line, complete with gi pin, lead thimble, and all accessories, conforming to is 731 / is 2544 complete all as specified and directed., preparation of detailed layout drawing in autocad and supply, fabrication, uv printing/engraving and fixing of 33 kv main receiving station layout, powerhouse no 2 layout and powerhouse no 1 layout on acp board, comprising site verification, preparation/finalization of single line diagram (sld) and equipment layout in autocad, submission for approval, high resolution uv printing or cnc engraving on minimum 3 mm thick aluminium composite panel (acp), protective coating, aluminium framing, and wall mounting complete in all respects., m & l for filling and spreading aggregate/stone using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc., m&l for surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed., m&l 150 mm thick soiling (or sub base) with broken boulders or quarried stone, interstices filled, suface formed and rolled and consolidated to required gradient and camber all as specified and directed., m&l for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed., m&l for pcc 1 4 8 type d 2 (40mm graded aggregate) in foundations, filling and mass concrete., m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., supply and fix led tube light fitting surface and wall mounted batten with 20 watts led including removal of old one complete all as specified and directed., m and l for earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point all as specified or indicated including testing on completion, excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed., removal of surplus soil to a distance not exceeding 50 m and depositing where directed by engr in charge., m&l for fixing gi tubing 15mm dia light grade use for the protection of earthing lead., m&l for fixing gi tubing 20mm dia light grade use for watering to earthing, m&l for funnel, wire mesh, lugs, nut, bolts etc, m&l for ms angle frame and sheet cover, m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) for earth pit chamber inclduing form work and finishing the surfaces even and smooth etc complete, m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete, m and l for disc type porcelain/polymer insulator vitreous 145 mm height and 255 mm diameter ball and socket type suitable for 11 000 volts grade complete with one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut complete in all respects as specified and as directed.
T18 Ref No : 16424008
Location : bardhaman , west bengal
Source : GEM Tenders
tender for supply laying and testing cable xlpe insulated screened pvc bedded galvanized steel strip size 185 sq mm 3.5 core , excavation in trenches not exceeding 1.5 m widthandnot exc 1.5m in depth getting out in soft loose soil etc. , excavation in trenches not exceeding 1.5 m widthandexc 1.5m in depth getting out in soft loose soil etc. , returning filling in including spreading levelling wateringandwell ramming in layers etc. , removal of surplus soil to a distance not exceeding 50 manddepositing where directed by engr in charge. , supplyandlay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm etc. , supplyandlay for dry clean dirtless river sand filling for cable protection with a layer of 8cm deep etc. , mandl for double wall corrugated dwc high density polyethylene pipes hdpe of 90mm etc. , mandl for fixing gi tubing 80mm dia light grade use for the protection of cable etc. , mandl for manual boring under road crossingandlaying pipe across the road etc. , sandf pcc cable route marker of size 900x300x70mm embossed with ht ug cable etc. , materialandlabour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc. , m and l for switch air break gang operated triple pole out door type unit on ht 11 kv 50 cycle etc. , m and l for 11 kv 200 amps outdoor type horn gap fuse set conforming to is 9385 etc. , m and l for cross arms bracing supports clampsandback plates fabricated from structural steel etc. , m and l for pin type porcelain polymer vitreous brown insulator of size 150mm height 150mm etc. , m and l for disc type porcelain polymer insulator vitreous 145 mm heightand255 mm diameter etc. , m and l for lightning arrester surge protector 11 kv grade heavy duty single pole etc. , s and f danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white etc. , mandl for cement concrete in foundations fillingandmass concrete etc. , mandl for pcc 1 3 6 type c2 using 40mm grade aggregate as in foundation etc. , mandl for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping etc. , m and l for earthing complete with galvanised steel earth plate electrode etc. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried etc. , mandl cable jointing kit for 11 kv earthed grade cable for outdoor termination heat shrink type joint etc. , m and l cable jointing kit for 11 kv earthed grade cable for straight through heat shrink type joint complete with jointing etc. , wrecking crow bar or claw bar as per is 706 (q3), supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11100 volts grade, of size 185 sq mm 3.5 core all as specifiedandas directed., excavation in trenches not exceeding 1.5 m widthandnot exc 1.5m in depth getting out in soft/loose soil all as s+b1+c2 c13+c2 c15+b1+c2 c13+c2 c2 c15, excavation in trenches not exceeding 1.5 m widthandexc 1.5m in depth getting out in soft/loose soil all as specifiedandas directed., returning filling in including spreading levelling wateringandwell ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specifiedandas directed., removal of surplus soil to a distance not exceeding 50 manddepositing where directed by engr in charge., supplyandlay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm complete all as specifiedanddirected., supplyandlay for dry, clean, dirtless river sand filling for cable protection with a layer of 8cm deep before layingand15cm covering above the top edge of cable after laying & punned down to required height, complete all as specifiedandas directed. note only punned thickness shall be measured & paid., m&l for double wall corrugated (dwc) high density polyethylene pipes (hdpe) of 90mm dia laid in trenches for cable protection complete all as spcifiedanddirected., m&l for fixing gi tubing 80mm dia light grade use for the protection of cable all as specifiedanddirected by engr in charge., m&l for manual boring under road crossingandlaying pipe across the road for laying cables complete all as specifiedandas directed., s&f pcc cable route marker of size 900x300x70mm, embossed with ht ug cable 11kv andexcavation of 40cm depth, grouted inandincluding pcc (1 2 4) type b 2 (using 20mm graded stone aggregate) complete all as specifiedanddirected., materialandlabour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 sp 55, 11.00 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ stricker, including painting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthatic paint & two strips of yellow/ sky blue paint (as per existing pattern through out the circumference of pole), including all internal surfacesandexternal surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specifiedandas directed complete all as specified. (note earth work, pcc work, shall be measuredandpaid separately.), m & l for switch air break gang operated triple pole out door type unit on ht 11 kv 50 cycle ac suitable for current rating upto 400 amps mechanically operated mounted on porcelain/polymer insulators (9 insulators)andframe with operating mechanism worked from ground level with earth switchandincluding locking arrangement, acsr conductor complete with taking down old unserviceable complete all as specifiedanddirected., m & l for 11 kv, 200 amps, outdoor type horn gap fuse set conforming to is 9385 (part i & ii) / relevant latest is standards, complete with galvanized steel horn assembly, suitable fuse element, heavy duty porcelain/polymer insulators, gi channel/angle mounting structure, connectors, clamps, nuts, boltsandall accessories, installed on pole mounted ht structure complete including taking down old unserviceable all as specifiedanddirected., m & l for cross arms , bracing, supports , clampsandback plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross armsandcomplete all as specifiedandas directed., m & l for pin type, porcelain/polymer, vitreous brown insulator of size 150mm height, 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washersandone galvanized iron nut complete all as specifiedandas directed., m & l for disc type porcelain/polymer insulator, vitreous, 145 mm heightand255 mm diameter, ballandsocket type, suitable for 11,000 volts grade, complete with one galvanized mild steel spindle, two galvanized iron washersandone galvanized iron nut, complete in all respects, as specifiedandas directed., m & l for lightning arrester/surge protector 11 kv grade heavy duty, single pole, self supporting station, expulsion type class 65 ka capacity with all fittings complete all with taking down old unserviceable all as specifiedanddirected., s & f danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figuresandconventional skullandbones in signal red colourandfixed with m.s. clamps, boltsandnuts of approved size, for ht, 25x20cm size complete all as specifiedanddirected., m&l for cement concrete in foundations, fillingandmass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 3 6 type c2 (using 40mm grade aggregate) as in foundation for pole etc complete all as specifiedandas directed., m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form workandfinishing the surfaces evenandsmooth etc complete all as specifiedanddirected., m and l for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4 mm as earth lead alongwith gi protection pipe by means of bolts nuts check nutsandwashers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test pointandpcc earth pitandci coverand funnel with watering pipe wire mesh earth lead protection pipe etc complete all as specified or indicated including testing on completion, m & l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete, m&l cable jointing kit for 11 kv (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materialandaccessories suitable for 3 core xlpe armoured aluminium conductor cable of size 185 sqmm 3 core, complete all as specifiedanddirected., m & l cable jointing kit for 11 kv (earthed) grade cable for straight through heat shrink type joint complete with jointing materialandaccessories suitable for 3 core xlpe armoured aluminium conductor cable of size 185 sqmm, complete all as specifiedanddirected.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16424015
Location : bardhaman , west bengal
Source : GEM Tenders
tender for supply laying and testing cable xlpe insulated screened pvc bedded galvanized steel strip or wire etc. , excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth etc. , excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth etc. , returning filling in including spreading levelling watering and well ramming in layers etc. , removal of surplus soil to a distance not exceeding 50 m and depositing etc. , supply and lay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm etc. , supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc. , m and l for double wall corrugated dwc high density polyethylene pipes hdpe etc. , m and l for fixing gi tubing 80mm dia light grade use for the protection of cable etc. , m and l for manual boring under road crossing and laying pipe across the road etc. , s and f pcc cable route marker of size 900x300x70mm embossed with ht ug cable etc. , material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc. , m and l for switch air break gang operated triple pole out door type unit etc. , m and l for 11 kv 200 amps outdoor type horn gap fuse set conforming to is 9385 etc. , m and l for cross arms bracing supports clamps and back plates fabricated etc. , m and l for pin type porcelain vitreous brown insulator of size 150mm etc. , m and l for lightning arrester surge protector 11 kv grade heavy duty single pole etc. , s and f danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled etc. , m and l for cement concrete in foundations filling and mass concrete type d2 1 etc. , m and l for pcc 1 3 6 type c2 using 40mm grade aggregate as in foundation etc. , m and l for pcc 1.2.4 type b1 using 20mm grade aggregate etc. , m and l for earthing complete with galvanised steel earth plate electrode 60x60cm etc. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten etc. , dismantling of acsr or aac conductors , dismantling concrete poles struts any size , dismantling cross arms of m.s. channel or angle sections etc. , dismantling insulators any type any size , pick axe as per is 273 (q4), supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 95 sq mm 3 core all as specified and as directed., excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed., removal of surplus soil to a distance not exceeding 50 m and depositing where directed by engr in charge., supply and lay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm complete all as specified and directed., supply and lay for dry, clean, dirtless river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying & punned down to required height, complete all as specified and as directed. note only punned thickness shall be measured & paid., m&l for double wall corrugated (dwc) high density polyethylene pipes (hdpe) of 90mm dia laid in trenches for cable protection complete all as spcified and directed., m&l for fixing gi tubing 80mm dia light grade use for the protection of cable all as specified and directed by engr in charge., m&l for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed., s&f pcc cable route marker of size 900x300x70mm, embossed with ht ug cable 11kv and excavation of 40cm depth, grouted in and including pcc (1 2 4) type b 2 (using 20mm graded stone aggregate) complete all as specified and directed., material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 sp 55, 11.00 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ stricker, including painting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthatic paint & two strips of yellow/ sky blue paint (as per existing pattern through out the circumference of pole), including all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed complete all as specified. (note earth work, pcc work, shall be measured and paid separately.), m & l for switch air break gang operated triple pole out door type unit on ht 11 kv 50 cycle ac suitable for current rating upto 400 amps mechanically operated mounted on insulators (9 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement, acsr conductor complete with taking down old unserviceable complete all as specified and directed., m & l for 11 kv, 200 amps, outdoor type horn gap fuse set conforming to is 9385 (part i & ii) / relevant latest is standards, complete with galvanized steel horn assembly, suitable fuse element, heavy duty porcelain/polymer insulators, gi channel/angle mounting structure, connectors, clamps, nuts, bolts and all accessories, installed on pole mounted ht structure complete including taking down old unserviceable all as specified and directed., m & l for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and complete all as specified and as directed., m & l for pin type, porcelain, vitreous brown insulator of size 150mm height, 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washers and one galvanized iron nut complete all as specified and as directed., m & l for lightning arrester/surge protector 11 kv grade heavy duty, single pole, self supporting station, expulsion type class 65 ka capacity with all fittings complete all with taking down old unserviceable all as specified and directed., s & f danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps, bolts and nuts of approved size, for ht, 25x20cm size complete all as specified and directed., m&l for cement concrete in foundations, filling and mass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 3 6 type c2 (using 40mm grade aggregate) as in foundation for pole etc complete all as specified and as directed., m and l for pcc 1.2.4 type b1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., m and l for earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4 mm as earth lead alongwith gi protection pipe by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point and pcc earth pit and ci cover and funnel with watering pipe wire mesh earth lead protection pipe etc complete all as specified or indicated including testing on completion., m & l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete, dismantling of acsr or aac conductors, dismantling concrete poles/ struts, any size, dismantling cross arms of m.s. channel or angle sections etc. complete and setting aside for re use with in 50m, dismantling insulators any type, any size

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Galvanised Foundation Bolt Including Nuts And Washers. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Galvanised Foundation Bolt Including Nuts And Washers sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Galvanised Foundation Bolt Including Nuts And Washers Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Galvanised Foundation Bolt Including Nuts And Washers, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Galvanised Foundation Bolt Including Nuts And Washers Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Galvanised Foundation Bolt Including Nuts And Washers Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Galvanised Foundation Bolt Including Nuts And Washers.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Galvanised Foundation Bolt Including Nuts And Washers depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Galvanised Foundation Bolt Including Nuts And Washers Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Galvanised Foundation Bolt Including Nuts And Washers bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Galvanised Foundation Bolt Including Nuts And Washers. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Galvanised Foundation Bolt Including Nuts And Washers, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Galvanised Foundation Bolt Including Nuts And Washers, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Galvanised Foundation Bolt Including Nuts And Washers?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Galvanised Foundation Bolt Including Nuts And Washers tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Galvanised Foundation Bolt Including Nuts And Washers?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Galvanised Foundation Bolt Including Nuts And Washers, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Galvanised Foundation Bolt Including Nuts And Washers is declared L1 and is generally awarded the contract