Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

640Latest Earthing installation Tenders List

Latest Earthing installation Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Earthing installation tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Earthing installation tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Earthing installation Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Earthing installation tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Earthing installation Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Earthing installation Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Earthing installation Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Earthing installation tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Earthing installation Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Earthing installation sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Earthing installation tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Earthing installation tenders.

Is EMD mandatory for all Earthing installation tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Earthing installation work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Earthing installation tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Earthing installation Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 17080736
Location : jaipur , rajasthan
NEW TENDER

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 17071359
Location : bangalore , karnataka
Source : GEM Tenders
NEW TENDER
corrigendum tender for removal of existing bituminous concrete layer , removal of existing synthetic astro turf surface , providing and laying bituminous concrete as per fih guidelines , removing and refixing of existing drain cover after relaying of hockey turf , earth work in excavation by mechanical or manual means in trenches or drains , providing and laying in position cement concrete of aggregate 40 mm , providing and laying in position cement concrete of aggregate 20 mm , steel work welded in built up sections or framed work , applying priming coat with ready mixed red oxide zinc chromate primer , painting with synthetic enamel paint , providing and fixing gi chain link fabric fencing of required width , supply and installation of fully computerized automatic and single key operation , supply, installation, testing and commissioning of 500 w led flood lights , supply, installation, testing and commissioning feeder pillar control panel , supply and installation of fih approved synthetic turf of green colour , supply installation testing and commissioning of dug out min 10 seating cap , supply and fixing of aluminium goal post for hockey , vendor to provide fih certification for global category , transportation charges of materials both removal and installation till site, re laying of existing astro turf hockey ground, removal of the existing bituminous concrete layer by milling machine to correct the ground gradient as per latest fih guidelines and removal of unserviceable materials from the site as per direction of tech rep or project officer including all costs loading and unloading carriage by mechanical means etc complete please refer to specification attached at appendix a ser no 1, removal of the existing synthetic hockey surface with rubber shock pad and disposal of the old unserviceable synthetic material including all costs loading and unloading carriage by mechanical means etc complete please refer to specification attached at appendix a ser no 2, providing and laying bituminous concrete strictly as per fih guidelines under the supervision of turf manufacturer representative or engineer using crushed stone aggregates of specified grading premixed with bituminous binder and filler transporting the hot mix to work site by tippers laying with paver finisher equipped with electronic sensor to the required grade alignment and level by special lazer equipment and rolling with smooth wheeled vibratory and tandem rollers to achieve the desired compaction and density as per specification complete and as per the direction of tech rep or project officer 50 mm compacted thickness with bitumen of grade vg 30 at the rate 5 point 5 percent by weight of total mix and lime filler at the rate of 3 percent by weight of aggregate prepared in batch type hot mix plant of 100 to 120 tph capacity please refer to specification attached at appendix a ser no 3, removing of existing drain cover and refixing after relaying of hockey turf including cleaning and minor repair work of drainage system as per direction of tech rep or project officer 12 mm cement plaster of mix 1 ratio 4 with 1 cement ratio 4 fine sand please refer to specification attached at appendix a ser no 4, earth work in excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains not exceeding 1 point 5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto to 1 point 5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m all kinds of soil please refer to specification attached at appendix a ser no 5, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level 1 ratio 4 ratio 8 with 1 cement ratio 4 coarse sand ratio 8 graded stone aggregate 40 mm nominal size please refer to specification attached at appendix a ser no 6, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level 1 ratio 2 ratio 4 with 1 cement ratio 2 coarse sand ratio 4 graded stone aggregate 20 mm nominal size please refer to specification attached at appendix a ser no 7, steel work welded in built up sections or framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc as required in grating frames guard bar ladder railings brackets gates and similar works please refer to specification attached at appendix a ser no 8, applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron or steel works please refer to specification attached at appendix a ser no 9, painting with synthetic enamel paint of approved brand and manufacture to give an even shade with two or more coats on new work please refer to specification attached at appendix a ser no 10, providing and fixing gi chain link fabric fencing of required width in mesh size 50 mm x 50 mm with height upto 6 m behind the goal posts and 2 point 5 m along the sides including strengthening with 2 mm dia wire or nuts bolts and washers as required complete as per the direction of tech rep or project officer made of gi wire of dia 4 mm please refer to specification attached at appendix a ser no 11, supply and installation of fully computerized automatic and single key operation with 6 pop up sprinkler system having a radius of 41 m at 6 bar pressure discharge of water specifically designed for synthetic sports hockey surface including all their fittings and accessories including earth work in excavation and re filling hdpe pipe dia 150 or 110 mm class pe 100 grade 12 point 50 kg per sqm minimum including all charges etc complete please refer to specification attached at appendix a ser no 12, supply installation testing and commissioning of 500 watts led flood lights wipro or bajaj or crompton or any equivalent brand with 12 lights x 4 nos on existing poles all as complete as required to fix lights on these poles please refer to specification attached at appendix a ser no 13, supply installation testing and commissioning of feeder pillar time control panel 3 ph with 16 amps mcb and amp power contactor installation of 12 light fixtures interlink connection cable for lights up to control panel please refer to specification attached at appendix a ser no 14, supply and installation of fih approved global category synthetic turf of pile height 13 mm alongwith cast in situ shock pad of minimum 15 mm thickness on prepared bituminous surface maintaining international hockey federation fih specification including all marking on the surface complete as per the instruction of tech rep or project officer the work shall be executed by an fih certified field builder and colour of the turf will be green please refer to specification attached at appendix a ser no 15, supply installation testing and commissioning of dug out with minimum 10 seating capacity of ss 304 and covering with polycarbonate sheets of approved shade with special turf wheels for movements etc as per directions of tech rep or project officer please refer to specification attached at appendix a ser no 16, supplying and fixing of aluminium goal post for hockey as per drawing design and specifications approved by fih including all fittings and net etc all complete as per direction of the tech rep or project officer please refer to specification attached at appendix a ser no 17, vendor to provide fih certification for global category for the project after completion of all wks please refer to specification attached at appendix a ser no 18 payment will be released after confirmation is received from fih certification authority, transportation charges of materials till site for deliveries and removal of debris from site out side the cantt premises please refer to specification attached at appendix a ser no 19
T18 Ref No : 17072842
Location : medchal , telangana
Source : GEM Tenders
NEW TENDER
tender for desert cooler , pedestal type fan , wall mounted fan , deep freezer , 2 ton inverter split ac , 1.5 ton inverter split ac , 1 ton split inverter ac , ups , solar led light, provision of desert coolers and other items for drdo at shamirpet, supply, installation, testing & commissioning of wood wool pads steel body evaporative coolers- desert cooler, sump tank capacity 100 ltrs minimum, nominal air delivery / capacity 5000 cubic meter per hour, floor standing without caster wheels, aluminum blade (for 5000 nominal capacity),fan size 500 mm for 5000 nominal capacity. maximum power consumption at zero static pressure 350 watts for 5000 nominal capacity, three speed motor, minimum bee 5 star efficiency or highest efficiency as applicable. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition and switch and socket arrangement., supply, installation, testing & commissioning of pedestal type air circulator electric fan having 600 mm sweep size , capacitor type motor, minimum air delivery 250 cubic meter per minute maximum input power 200 watt for 600mm sweep,rated voltage 240 volt ac, 50hz, minimum bee 5 star efficiency or highest efficiency as applicable. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition and switch and socket arrangement., supply, installation, testing & commissioning of 400mm sweep wall mounted electric fan having 400 mm sweep size , capacitor type motor, minimum air delivery 65 cubic meter per minute maximum input power 61 watt for capacitor type and 73 watt for non- capacitor type fan for 400 mm sweep,rated voltage 230 volt ac, 50hz, 03 speed steps with rotary switch speed control mechanism and maximum speed 1300 rpm, angular movement 90 degree, minimum bee 5 star efficiency or highest efficiency as applicable. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition and switch and socket arrangement., supply, installation, testing & commissioning of horizontal deep freezer having capacity 400 ltrs, temp set value minus 20 deg c, external dimensions 155mm x 600mm x 600mm. refrigerants eco friendly non flammable,non cfc refrigerants cool down time less than 6 hours from ambient to set point, durable inner doors for each compartment, main door with inner frp lining and durable magnetic gasket. rated voltage 230 volt, 50 hz ac supply. minimum bee 5 star efficiency or highest efficiency as applicable. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition and switch and socket arrangement., supply, installation, testing & commissioning of 2 ton wall mount split ac (indoor and outdoor included) having 6000 kcal/hr with tolerance +/- 10%, eco friendly r32 refrigerant, rated voltage 230 volt, 50 hz ac supply, minimum bee 5 star efficiency or highest efficiency as applicable with the following features only bis marked, compressor type inverter variable speed, copper evaporator and condenser, reusable air filter and standard accessories 3 meter refrigerant interconnecting copper pipe with additional length as per site requirement, 1 meter pvc insulated sheathed power cable (as per is 694), drain pipe, remote, minimum two years standard warranty on air conditioner, warranty on compressor 10.0 years, warranty on pcb, 5.0 years, voltage stabiliser, 16a mcb with enclosure, mounting stand arrangement for outdoor unit. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition., supply, installation, testing & commissioning of 1.5 ton split ac (indoor and outdoor included) having 4500 kcal/hr with tolerance +/- 10%, eco friendly refrigerant rated voltage 230 volt, 50 hz ac supply minimum bee 5 star efficiency or highest efficiency as applicable with the following features only bis marked, compressor type as per bee star rating label inverter variable speed, wall mount type split air conditioner with copper evaporator and condenser, reusable air filter and standard accessories 3 meter refrigerant interconnecting copper pipe with additional length as per site requirement, 1 meter pvc insulated sheathed power cable (as per is 694), drain pipe, remote, minimum two years standard warranty on air conditioner, warranty on compressor 10.0 years, warranty on pcb, 5.0 years voltage stabiliser 16a mcb with enclosure mounting stand arrangement for outdoor unit. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition., supply, installation, testing & commissioning of 1 ton split ac (indoor and outdoor included) having 3000 kcal/hr with tolerance +/- 10%, eco friendly refrigerant rated voltage 230 volt, 50 hz ac supply minimum bee 5 star efficiency or highest efficiency as applicable with the following features only bis marked, compressor type as per bee star rating label inverter variable speed, wall mount type split air conditioner with copper evaporator and condenser, reusable air filter and standard accessories 3 meter refrigerant interconnecting copper pipe with additional length as per site requirement, 1 meter pvc insulated sheathed power cable (as per is 694), drain pipe, remote, minimum two years standard warranty on air conditioner, warranty on compressor 10.0 years, warranty on pcb, 5.0 years voltage stabiliser 16a mcb with enclosure mounting stand arrangement for outdoor unit. additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition., supply, installation, testing and commissioning of 1 kva ups, high efficiency, sine filtered, unity power factor, thd within ieee 519 2024 standards with ip65 enclosure, supporting bracket and connecting accessories including earthing to the nearest point with the following features only bis marked makes input voltage (ac, 50 hz) single phase, 160v to 260v output voltage (ac, 50 hz) single phase, 230v with 1 percent tolerance availability of inbuilt isolation transformer yes type of battery smf-vrla (sealed maintenance free-valve regulated lead acid) stationary lead acid batteries backup time ( min ) 15 type of mounting of online ups floor standing operating temperature range (lower limit) 5deg c to 0 degc operating temperature range (upper limit) 45deg c to 50deg c minimum standard warranty five (05) years additional wiring if the power point distance is more than 1 meter along with pvc casing, caping along the wall or inside the false ceiling as per the site condition and switch and socket arrangement., supply, installation, testing and commissioning of ip 65 90 watt solar led light with inbuilt solar panel on the existing 9m pole with the following features brightness minimum 9000 lumens solar panel minimum 30w and matching with the battery ratings monocrystalline solar cells battery capacity 12v 24ah lifepo4 backup autonomy 2 to 3 rainy days (overcast weather reserve) enclosure material die cast aluminium charging time 4 to 6 hours of full sunlight lighting time 12 to 15 hours (or dusk-to-dawn) warranty three (03) years

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 17075562
Location : cachar , assam
Source : GEM Tenders
NEW TENDER
tender for providing operation and maintenance services of electrical and mechanical installations for 1st year , providing maintenance services and operation of electrical and mechanical installations for 2nd year , providing operation and maintenance services of glf system for 1st year , providing operation and maintenance services of glf system for 2nd year , deploying 03 nos high skilled computer operator as per scope of work given in special conditions of contract for 1st year , complete overhuling and repairing of 3.5 hp capacity water pump , complete re- winding of burnt out stator coils of 3 ph. 3.5 hp induction motor , complete overhuling and repairing of 7.5 hp capacity water pump , complete re-winding of burnt out stator coils of 3 ph. 7.5 hp induction motor , cleaning and painting of street light tubular pole including light fitting bracket and all other associated accessories of height above 5 mtr upto 12 mtr , cleaning and painting of street light tubular pole including light fitting bracket and all other associated accessories of height upto 05 mtr , painting of collar of street light pole , painting of glf fittings mirl including base plate , painting of outdoor feeder panel or lt panel , replacement of damage street light loop-in loop- out box , carrying out of dsr item works as scheduled in dsr -2025, job contract for e and m installations at terminal building operational area and allied works, providing operation and maintenance services of electrical & mechanical installations i.e power supply system, electrical installation of terminal building, operation area, car parking area, street light, civil office, covering the scope of operation, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 01 no high skilled, 05 nos skilled, 01 no. semi-skilled and 02 nos unskilled manpowers (including reliever) as per scope of work given in additional terms of contract to ensure round the clock operation by providing adequate manpower (i.e. in three shifts basis, each shift of 8 hours) on all days including sundays & national holidays as per direction of eic. a) for 1st year, providing operation and maintenance services of electrical & mechanical installations i.e power supply system, electrical installation of terminal building, operation area, car parking area, street light, civil office, covering the scope of operation, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 01 no high skilled, 05 nos skilled, 01 no. semi-skilled and 02 nos unskilled manpowers (including reliever) as per scope of work given in additional terms of contract to ensure round the clock operation by providing adequate manpower (i.e. in three shifts basis, each shift of 8 hours) on all days including sundays & national holidays as per direction of eic. b) for 2nd year, providing operation and maintenance services of glf systems at operational area (comprising of mirl/ taxi apron /guidance illuminated signage /afl cables etc.) covering the scope of operation, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 02 nos skilled, 01 no semi-skilled and 02 nos unskilled manpowers (including reliever) as per scope of work given in additional terms of contract to ensure round the clock operation by providing adequate manpower (i.e. in three shifts basis, each shift of 8 hours) on all days including sundays & national holidays as per direction of eic. a) for 1st year, providing operation and maintenance services of glf systems at operational area (comprising of mirl/ taxi apron /guidance illuminated signage /afl cables etc.) covering the scope of operation, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 02 nos skilled, 01 no semi-skilled and 02 nos unskilled manpowers (including reliever) as per scope of work given in additional terms of contract to ensure round the clock operation by providing adequate manpower (i.e. in three shifts basis, each shift of 8 hours) on all days including sundays & national holidays as per direction of eic. b) for 2nd year, providing of services for preperation of various reports, maintaining the records, preparation of rate analysis, estimates, tender documents, sap billings etc along with various day to day office works by deploying 03 nos high skilled computer operator as per scope of work given in special conditions of contract on all days excluding sundays and national holidays & as per direction of eic. for 1st year, complete overhuling & repairing of 3.5 hp capacity water pump i/c replacement of defective keys, necessary lathe work, replacement of ball bearing & gland packing including replacement of bush bearing, replacement of minor hardware items and painting after dismantling from the existing location, transporation upto the workshop if necessary & reinstallation of the same, testing etc complete as required as per site condition. location - overhead refining for cft at apron area, complete re-winding of burnt out stator coils of 3 ph. 3.5 hp induction motor along with removal of the burnt out copper coil/wire and providing new super anamel coated copper with insulation and varnishing with suitable quality of varnish and replacement of minor wornout hardware items etc. as required i/c giving less credit for the burnt out copper coil. location - overhead refining for cft at apron area, complete overhuling & repairing of 7.5 hp capacity water pump i/c replacement of defective keys, necessary lathe work, replacement of ball bearing & gland packing including replacement of bush bearing, replacement of minor hardware items and painting after dismantling from the existing location, transporation upto the workshop if necessary & reinstallation of the same, testing etc complete as required as per site condition. location - water treatment plant, complete re-winding of burnt out stator coils of 3 ph. 7.5 hp induction motor along with removal of the burnt out copper coil/wire and providing new super anamel coated copper with insulation and varnishing with suitable quality of varnish and replacement of minor wornout hardware items etc. as required i/c giving less credit for the burnt out copper coil. location - water treatment plant, cleaning and painting of street light tubular pole including light fitting bracket and all other associated accessories of height above 5 mtr upto 12 mtr with one coat of red-oxide metal primer of anti-corrosive paint on rusted surface and one or more coats of enamelled paint including numbering on the pole etc as required. the pole shall be painted with obstruction color upto required height above the masonary pedestal ( 1.0 to 1.5m) as per direction of eic., cleaning and painting of street light tubular pole including light fitting bracket and all other associated accessories of height upto 05 mtr with one coat of red-oxide metal primer of anti-corrosive paint on rusted surface and one or more coats of enamelled paint including numbering on the pole etc as required. the pole shall be painted with obstruction color upto required height above the masonary pedestal ( 1.0 to 1.5m) as per direction of eic., painting of collar of street light pole with one or more coat of synthetic enamelled paint and application of red-oxide paint wherever required in bicolour ( black and yellow strip ) complete etc as required and as per direction of eic., painting of glf fittings (mirl) including base plate with one or more coats of synthetic enamelled paint of required colour as per icao standard of approved make to give an even shade including cleaning the surface and numbering of the same etc.as required & as per direction of eic., painting of outdoor feeder panel / lt panel at switch room in all area with one coat of metal primer of anti-corrosive paint on rusted surface and two coats of approved synthetic enamel paint. the outdoor feeder panel should be painted by alternate white and red colour strips of suitable size for operartional area complete as required as per direction of e.i.c., replacement of damage street light loop-in loop-out box by ip 66 thermoplastic polycarbonete enclosure (minimum size 350x250x122) which is totally shock proof,safe, weather proof, rust proof, dust proof, water proof, halogen free silica free and having internally embeded gasket technology. the enclosure should have 04 nos of 25 sqmm elmax terminal to accomodate 4 x 25 sqmm lt cable, 1 no sp 6 amp mcb of approved make ms clamp for pole mounting completed as required i/c dismantling the existing loop-in loop-out box, cable connection, earthing etc and reconnection the same with the new cable gland, earthing connection etc as complete as required., carrying out of dsr item works as scheduled in dsr -2025 (internal and external) cpwd as and when required basis & as per direction of engineer in charge. (note - the firm has to quote/upload the percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below - for example - if desired to quote 5% above on special repair 2025 rates, the rate column shall be filled as 1.05. if desired to quote 3% below on special repair 2025 rates, the rate column shall be filled as 0.97.)
T18 Ref No : 17076166
Location : cachar , assam
Source : GEM Tenders
NEW TENDER
tender for providing operation and maintenance services of electrical and mechanical installations for 1st year , providing operation and maintenance services of electrical and mechanical installations for 2nd year , day to day operation and maintenance of water pump house for 1st year , day to day operation and maintenance of water pump house for 2nd year , filtration and dehydration of insulation oil of existing ht installations , servicing testing checking and calibration of relay installed in 11 kv ht panel for 1st year , servicing testing checking and calibration of relay installed in 11 kv ht panel for 2nd year , calibration and testing of 8 nos air circuit breaker for 1st year , calibration and testing of 8 nos air circuit breaker for 2nd year , complete overhauling and repairing of 10 hp capacity water pump , complete re-winding of burnt out cooper coils of stator of 10 hp capacity , complete overhauling and repairing of 30 hp capacity , complete re-winding of burnt out cooper coils of stator of 30 hp capacity , replacement of 12 v 180 ah battery for dg set complete as required , replacement of 12 v 100 ah battery for dg set complete as required , carrying out of dsr item works as scheduled in dsr -2025, job contract for e and m installations at 11 kv substation and water pump house and allied works, providing operation & maintenance services of electrical & mechanical installations viz power supply system of 11 kv substation/power house, cts, transformers, avrs & ht & lt panels, apfc panel, dg sets, synchronizing panels, covering the scope of operation, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 08 nos. skilled, 01 no. semi-skilled and 03 nos. unskilled manpower (including reliever) as per scope of work given in additional terms of contract to ensure round the clock operation by providing adequate manpower (i.e. in three shifts basis, each shift of 8 hours) on all days including sundays & national holidays as per direction of eic. a) for 1st year, providing operation & maintenance services of electrical & mechanical installations viz power supply system of 11 kv substation/power house, cts, transformers, avrs & ht & lt panels, apfc panel, dg sets, synchronizing panels, covering the scope of operation, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 08 nos. skilled, 01 no. semi-skilled and 03 nos. unskilled manpower (including reliever) as per scope of work given in additional terms of contract to ensure round the clock operation by providing adequate manpower (i.e. in three shifts basis, each shift of 8 hours) on all days including sundays & national holidays as per direction of eic. b) for 2nd year, day to day operation & maintenance of water pump house of all types and capacities water pump sets, i/c lighting & power supply system attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 04 nos skilled and 03 nos unskilled manpower (including reliever) as per scope of work given in additional terms of contract to ensure round the clock by providing adequate manpower (i.e. in three shifts basis , each shift of 8 hours) on all days including sundays & national holidays & as per direction of eic. a) for 1st year, day to day operation & maintenance of water pump house of all types and capacities water pump sets, i/c lighting & power supply system attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, performing preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintaining of records in all pmi register etc. by deploying 04 nos skilled and 03 nos unskilled manpower (including reliever) as per scope of work given in additional terms of contract to ensure round the clock by providing adequate manpower (i.e. in three shifts basis , each shift of 8 hours) on all days including sundays & national holidays & as per direction of eic. b) for 2nd year, filtration & dehydration of insulation oil of existing ht installations (like- ht avrs & 11 kv indoor transformer) in substation using on line oil filtration equipment with initial heating arrangement to attain standard breakdown voltage including testing of breaking strength prior and post purification with certificate and replacement of silica gel of breather of the same etc as required and as per direction of engg-in-charge. location - sub station, servicing , testing , checking and calibration of relay (over current 2 nos + 1 no earth fault relay) installed in 11 kv ht panel including calibration and testing of 03 nos vcb (400 amp) 11 kv ht - cg make with suitable secondary injection kit and submission of test certificate completed as required, checking the function of auxiliary relay ( confirming the tripping) mechanism of the breaker due to high winding temperature, high oil temperature and due to bucholz relay , activation of the connection transformer, testing the of tripping system by secondary injection kit, tightning the terminals and termination, changing of all nuts and bolts i/c washers (if required), replacement of all insulator/bushing of 11 kv panel (01 incomer and 02 no outgoing+ insulators of pt section) (if required), replacement of the cork sheet and replacement of 3 sets of indoor type resin cast cts (if required) i/c pressure test at site and calibrating the same complete as required and as per direction of engg-in-charge. location - sub station a) for 1st year, servicing , testing , checking and calibration of relay (over current 2 nos + 1 no earth fault relay) installed in 11 kv ht panel including calibration and testing of 03 nos vcb (400 amp) 11 kv ht - cg make with suitable secondary injection kit and submission of test certificate completed as required, checking the function of auxiliary relay ( confirming the tripping) mechanism of the breaker due to high winding temperature, high oil temperature and due to bucholz relay , activation of the connection transformer, testing the of tripping system by secondary injection kit, tightning the terminals and termination, changing of all nuts and bolts i/c washers (if required), replacement of all insulator/bushing of 11 kv panel (01 incomer and 02 no outgoing+ insulators of pt section) (if required), replacement of the cork sheet and replacement of 3 sets of indoor type resin cast cts (if required) i/c pressure test at site and calibrating the same complete as required and as per direction of engg-in-charge. location - sub station b) for 2nd year, calibration and testing of 8 nos air circuit breaker (make - l&t) of capacity (range - 800 amp - 5 nos & 1250 amp - 3 nos) from oem authorize service dealer using suitable secondary injection kit and submission of test certificate completed as required. location - sub station a) for 1st year, calibration and testing of 8 nos air circuit breaker (make - l&t) of capacity (range - 800 amp - 5 nos & 1250 amp - 3 nos) from oem authorize service dealer using suitable secondary injection kit and submission of test certificate completed as required. location - sub station b) for 2nd year, complete overhauling & repairing of 10 hp capacity water pump i/c replacement of defective keys, bush, necessary lathe work, replacement of ball bearing & gland packing, painting and replacement of worn out minor hardware items etc. after dismantling from the existing location, transportation up to the workshop if necessary & reinstallation of the same, testing etc complete as required as per site condition. location - water pump house colony, complete re-winding of burnt out cooper coils of stator of 10 hp capacity 3 ph. induction motor, dismantling from the existing location, transporting upto the workshop and reinstallation of the motor after repair with new super enamel coated copper, heat burnishing along with all other necessary spare parts as required including giving less credit for the burnout copper coil complete as required. location - water pump house colony, complete overhauling & repairing of 30 hp capacity ie3 (energy efficient) water pump i/c replacement of defective keys, bush, necessary lathe work, replacement of ball bearing & gland packing, painting and replacement of worn out minor hardware items etc. after dismantling from the existing location, transportation up to the workshop if necessary & reinstallation of the same, testing etc complete as required as per site condition. location - water pump house salganga, complete re-winding of burnt out cooper coils of stator of 30 hp capacity ie3 3 ph. induction motor, dismantling from the existing location, transporting up to the workshop and reinstallation of the motor after repair with new super enamel coated copper, heat burnishing along with all other necessary spare parts as required including giving less credit for the burnt-out copper coil complete as required. location - water pump house colony, replacement of 12 v 180 ah battery for d.g set complete as required., replacement of 12 v 100 ah battery for d.g set complete as required., carrying out of dsr item works as scheduled in dsr -2025 (internal and external) cpwd as and when required basis & as per direction of engineer in charge. (note - the firm has to quote/upload the percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below - for example - if desired to quote 5% above on special repair 2025 rates, the rate column shall be filled as 1.05. if desired to quote 3% below on special repair 2025 rates, the rate column shall be filled as 0.97.)

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16877538
Location : kamrup , assam
Source : GEM Tenders
LIVE TENDER
tender for wall cladding , upvc window , window glazing , window blind , painting , allied works , mcb 1 , mcb 2 , wiring , pvc conduit 1 , pvc conduit 2 , modular blanking plate , pvc box 1 , pvc box 2 , pvc box 3 , modular switch 1 , modular switch 2 , modular switch 3 , modular switch 4 , wiring 1 , wiring 2 , wiring 3 , itc , led light 2, renovation of zmc chamber at esdic ro guwahati, providing & fixing in position phenol bonded bamboowood wall cladding at all height with planks of sizes 10mm thick, minimum 1800mm length and minimum 100 mm wide as detailed in the detailed boq enclosed with the nit document, providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension as detailed in the detailed boq enclosed with the nit document, providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge, providing and fixing window blind, including complete in all respect as per the direction of engineer in-charge., distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per specification provided, allied works as per the boq and item-wise specifications enclosed with the nit document, supplying and fixing 5 a to 32 a rating 240/415 v miniature circuit breaker as detailed in the detailed boq enclosed with the nit document, supplying and fixing 40a rating double pole 240 volts isolator in the existing mcb db as detailed in the detailed boq enclosed with the nit document, wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable as detailed in the detailed boq enclosed with the nit document, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- 20mm dia, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- 25 mm dia, supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., supplying and fixing gi/pvc box alongwith modular base & cover plate for modular switches in recess etc.as required- 3 module (100mmx75mm), supplying and fixing gi/pvc box alongwith modular base & cover plate for modular switches in recess etc.as required- 6 module (200mmx75mm), supplying and fixing gi/pvc box alongwith modular base & cover plate for modular switches in recess etc.as required- 8 module (125mmx125mm), supplying and fixing modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required- 5/6 a switch, supplying and fixing modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required- 3 pin 5/6 a socket outlet, supplying and fixing modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required- 15/16a switch, supplying and fixing modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required- 6 pin 15/16 a socket outlet, wiring for circuit/ submain wiring alongwith earth wire - 1 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, wiring for circuit/ submain wiring alongwith earth wire - 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, wiring for circuit/ submain wiring alongwith earth wire - 2 x 4 sq. mm + 1 x 4 sq. mm earth wire, installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, supplying of ceilling mounted 22 watt indoor type led light fittings as detailed in the detailed boq enclosed with the nit document

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Earthing Installation. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Earthing Installation sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Earthing Installation Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Earthing Installation, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Earthing Installation Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Earthing Installation Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Earthing Installation.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Earthing Installation depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Earthing Installation Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Earthing Installation bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Earthing Installation. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Earthing Installation, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Earthing Installation, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Earthing Installation?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Earthing Installation tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Earthing Installation?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Earthing Installation, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Earthing Installation is declared L1 and is generally awarded the contract