Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

42Results forLatest Cable trench cover Tenders List

Latest Cable trench cover Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Cable trench cover tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Cable trench cover tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Cable trench cover Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Cable trench cover tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Cable trench cover Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Cable trench cover Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Cable trench cover Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Cable trench cover tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Cable trench cover Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Cable trench cover sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Cable trench cover tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Cable trench cover tenders.

Is EMD mandatory for all Cable trench cover tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Cable trench cover work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Cable trench cover tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Cable trench cover Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16141546
new Tender
Location : jammu , jammu & kashmir
Source : GEM Tenders
new Tender

corrigendum tender for supply laying testing and commissioning ug cable xlpe , material and labour for cable jointing kit end joint for 11 kv , excavating in trenches in hard dense soft soil n exc 1.5 m wide , removing excavated material to a distance not exceeding 50 mtr , returing filling in including spreading levelling watering , material and labour for sand cushioning 8 cm before laying ht lt , material and labour for un- reinforced precast concrete cable , supply and fixing pin type porcelain vitreous white , supply and fixing disc type insulator porcelain vitreous , taking down and supply and fixing acsr conductor , material and labour for earth continuity conductor, repair and maintenance of acsr overhead conductor including connected items, supply laying testing and commissioning ug cable xlpe insulated screened pvc bedded galvanized steel strip or wire armoured electric power cables heavy duty 11000 volts grade with stranded aluminium conductor of size 185 sq mm 3 core including taking down old cable with suitable thimbles from trench complete., material and labour for cable jointing kit end joint for 11 kv earthed grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm to 185 sqmm., excavating in trenches in hard dense soft soil n exc 1.5 m wide and n exc 1.5 m in depth for foundation of poles trenches for laying of cable or for shafts wells cesspits manholes pier holes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed., removing excavated material to a distance not exceeding 50 mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point., returing filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm each all as required and directed., material and labour for sand cushioning 8 cm before laying ht lt underground cable in trenches and 15 cm after the cable is laid and all as specified and directed by engr in charge. note. the laid sand shall be gently punned down by hand.the punned thickness only shall be measured and paid., material and labour for un-reinforced precast concrete cable cover class hv type-1 size 300x180x40mm complete all as specified and direction., supply and fixing pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150mm height 150mm dia for 11000 volts grade complete., supply and fixing disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type white brown or green two-in-series assembly for tension with tension clamps for conductors working pressure 11000 volt complete., taking down and supply and fixing acsr conductor of size mink complete, material and labour for earth continuity conductor or main earthing lead using 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down old wire complete


Agency / Dept : indian army
Tender Value : 0
Due Date : Jul 09, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16022012
live Tender
Location : lucknow , uttar pradesh
Source : GEM Tenders
live Tender

corrigendum tender for main fire pump , diesel driven pump , jockey pump , terrace pump , control panel , starter , m s pipe , internal hydrant valve , external yard hydrant valve , butterfly valve , sfc of butterfly valve , orifice plate , pitc non return valve , stainless steel y strainer , pitc of stainless steel y strainer , hose pipe , first aid hose reel , short branch pipe , fire brigade connection , foot valve , air vessel , pressure switch , pressure gauge , control valve , hose cabinet , cutting holes , supply of cable , laying of cable , end termination , fire cable , cable tray , earthing , gi strip , gi strip , earth wire , gi pipe, pitc of fire fighting with wet riser system, sh 1 wet riser system main fire pump a supplying, installation, testing and commissioning of electric driven main fire pump conforming to is 12469 2019 suitable for automatic peration and consisting of following complete in all respects as required. b horizontal type multistage centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft fire pump capable for delivery of 2280 lpm against atotal head of 70 mtrs approximately while running at 1450 1500 rpm mechanical seal as required bsnl approved make. c suitable hp squirrel cage induction motor tefc synchronous speed 1500 rpm suitable for operation on 415 volts 3 phase 50 hz ac supply with ip 55 protection for enclosure horizontal foot mounted type with class. f insulation conforming to is 12615 2018. d m.s. fabricated common base plate coupling,coupling guard, foundation bolts etc. as required. e suitable cement concrete foundation duly plastered with anti vibration pads note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point.the pump room is situated on the underground water tank. 2280 lpm at 70 m head, diesel driven pump a supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to is 12469 2019 suitable for automatic operation and nsisting of following,complete in all respects, as required.diesel driven pump. b horizontal type, multistage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 lpm against atoatl head of 70 mtrs approxi as required.c suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.d m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.e suitable cement concrete foundation duly plastered and with anti vibration pads.note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. the pump room is situated on the underground water tank.2280 lpm at 70 m head, jockey pump a supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to is 12469 2019 suitable for automatic operation and consisting of following, complete in all respects as required jockey pump.b horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 12615 2018. d m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) suitable cement concrete foundation duly plastered and with anti vibration pads.note the pump room is situated on the underground water tank. 180 lpm at 70 m head, supplying, installation, testing and commissioning of electric driven terrace pump conforming to is 12469 2019 suitable for automatic operation and consisting of following,complete in all respects, as required terrace pump b horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is-12615 2018. d m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.e suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m head, control panels fabrication supplying installation testing and commissioning of electrical control panel of cubical construction floor mounted type fabricated out of 2mm thick crca , apartmentalised with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper copper strip, having switchgears and accessories, mountings and internal wiring earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurization pump and diesel pump set complete as per cpwd specification and atc attached for main fire pump , jockey pump, diesel pump with system controller as per as per atc attached, supply installation testing and commissioning of fully automatic dol starter for terrace pump terrace pump siutable for operation on 3 phase 415 volt ac supply i/c making inter connection testing etc as requiored at site., sh ii pipes and accessories.providing laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class -ii of is 3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 50 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 mm dia wall thickness 6.3 mm, supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required.single headed gunmetal, supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal/stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required. single headed gunmetal, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required . 50mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .80 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .100 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .150 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .200 mm dia, supplying and fixing orifice plate made out of 6 mm thick stainless steel grade 304 with orifice of required size to be fitted between flange and landing valve of external and internal e pressure at the outlet to the level of 3.5 kg/cm2 complete as required., providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 50mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 80 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 100 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 150 mm dia., providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 80 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia, supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and femalecouplings duly bound with gi wire, rivets etc conforming to is 636 type a as required. gun metal., supplying and fixing first aid hose reel with ms construction spray painted in post office red,conforming to is 884 complete with the following as required.a 20 mm nominal internal dia. water hose thermoplastic textile reinforced type 2 as per is 12585 b 20 mm nominal internal dia gun metal globe valve and nozzle. c drum and brackets for fixing the equipmets on wall. d connections from riser with 25 mm dia stop gun metal valve and m.s. pipe and socket. 30 mtrs, supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.gun metal., supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required. 2 way 100 mm dia m.s. pipe, supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required.4 way 150 mm dia m.s. pipe., providing, installation, testing and commissioning of c.i flanged swing type foot valve isi marked of following sizes confirming to is 4038 complete with all acessories complete etc as required.200 mm dia., supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required., providing and fixing of pressure switch in m.s. pipe line including connection etc. as required., providing and fixing in position industrial type pressure gauge with gun metal / brass valves complete etc. as required., providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, ms pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required. 150 mm dia, supplying and fixing of hose cabinet of size 750 mm 600 mm 250 mm made of 2 mm thick ms sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve , 2 nos . 15 mtr. long hose pipe, 1 no branch pipe, mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect , for external hydrant ,as required., cutting holes up to 15cm and 15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 2 4 1 cement 2 coarse sand graded stone aggregate 20 mm nominal size, including finishing complete so as to make it leak proof., sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 4 core 16 sqmm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988 . 3.5 core 25 sq. mm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 3.5 core x 70 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 35 sq. mm and upto 95 sq. mm clamped with 25 mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 185 sq. mm and upto 400 sq. mm clamped with 40mm and 3mm ms flat clamp, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq. mm clamped with 1mm thick saddle., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 35 sq. mm and upto 95 sq. mm clamped with 25mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 185 sq. mm and upto 400 sq. mm clamped with 40mm 3mm ms flat clamp, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.mm above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 4 core 16 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 25 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 70 sq. mm size 38mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 300 sq. mm size 70mm, supplying and laying of 2core 1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring and frls/hffr outer sheath complete as required., supplying and installaton following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5 percent, in convenient sections, joined with connectors, suspended from the ceiling with two numbers ms/gi suspenders including base of suitable size ms/gi angle, bolts and nuts, painting suspenders, fastener etc as required. 100 mm wide , 50 mm depth , 1.6 mm thickness, earthing with g.i. earth plate 600 mm length x 600 width and 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip on surface or in recess for connections etc. as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., providing and fixing following sizes g.i. pipes complete with g.i. fittings including trenching and refilling etc. 80 mm dia nominal bore


Tender Value : 5995340
Due Date : Jul 14, 2026
T18 Ref No : 16084241
live Tender
Location : jammu , jammu & kashmir
Source : GEM Tenders
live Tender

tender for supply installation testing and commissioning of pu coated in black colour for high including 32 number of poles , providing installation of decorative integral gate led light fittings made of alluminium housing fitted , supply installation testing and commissioning of pu coated in black colour for high corrosion resistance , supply installation testing and commissioning of 5 7 watt led type shrub up lighter for landscape lighting complete with integral heavy duty electronic , excavating trenches of required width for pipes cables etc including excavation for sockets depth upto , casting of foundation earth work in excavation by manual means in trenches for , providing and laying in position cement concrete of specified grade including curing but excluding the , providing and laying in position specified grade of reinforced cement concrete including curing but excluding , centering and shuttering including strutting propping etc and removal of form for colon foundations footings bases , supply laying testing and commissioning of aluminium slash copper conductor cable pvc insulated armoured pvc sheathed , supply laying testing and commissioning of aluminium slash copper conductor cable pvc insulated armoured pvc sheathed 1100 volts , wiring for circuit wiring along with earth wire with 3 core 2dot5 sq mm fr pvc insulated flexible copper conductor as required , wiring for circuit wiring along with earth wire with 3 core 1dot5 sq mm fr pvc insulated flexible copper conductor as required , supply and fixing of following sizes of pvc conduit along with accessories in surface slash recess including cutting , demolishing cement concrete slash marble flooring slash road manually or by mechanical means including disposal , providing and laying cement concrerte mix for filling the demolished portion of cement concrete outdoor flooring , supply laying jointing testing and commissioning of isi marked is colon 14930 part 2 hdpe dwc double wall corrugated , dismantling of interlocked tiles slash sand stone tiles before excavation work and making the good as by re fixing , supply and fixing of new tiles in place of broken slash damaged tiles 20 percent of dismantled tiles including sand coushning as required , dismantling slash demolishing of old foundations manually slash by mechanical means including disposal of , disposal of mulbaslashwaste outside the ndmc limits by mechanical means , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry , providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc as required , earthing with gi earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure , supplying and laying 25 mm x 5 mm gi strip at 0dot50 metre below ground as strip earth electrode including connection , providing and fixing 25 mm x 5 mm gi strip on surface or in recess for connections etc as required , providing and fixing 6 swg dia gi wire on surface or in recess for loop earthing as required , construction of man hole with 9inch brick work and rcc top cover 2dot5ft x 2dot5ft to enclose the masonry enclosure, boq items, check atc for more details


Tender Value : 0
Due Date : Jul 18, 2026
T18 Ref No : 16085077
live Tender
Location : pachpadra , rajasthan
Source : GEM Tenders
live Tender

corrigendum tender for s,i,t,c nflp perimeter camera , s,i,t,c nflp ptz camera , s,i,t,c indoor dome camera , s,i,t,c non flp fixed camera , s,i,t,c cctv server , s,i,t,c nas-cctv , s,i,t,c vms software , s,i,t,c server rack, 42u , s,i,t,c client cctv machine , s,i,t,c 55inch led tv , s,i,t,c 4 port managed switch , s,i,t,c 12 port managed switch , s,i,t,c ntwrk mntr softwr , s,i,t,c non-flp jb , sandf 8m gi pole , sandf 10m gi pole , sup 3cx4sqmm cu cble, 1.1kv , lay cable upto 10sqmm , sup and lay cat6 arm cble , sup and lay cat6 unarm cble , sup and lay 6c ofc cble , construction cble trench , sup and lay 50mm gi pipe , sandf 100x50mm cable tray , lay of cable tray , s-cctv mandat spares , s,c,t earthpit , sandf 4sqmm earthwire , sandf 25x3mm earthstrip , sandf 50x6mm earthstrip , sup struct steel , fanderect steel , camc for cctv and pa system , sup mcs without touchscreen , erect of mcs , sup horn spkr ip-poe nflp , iandc horn spkr ip-poe nflp , sup box_cone spkr , e,t,c box_cone spkr , sandf hdpe pipe 50mm , sup 5kva redundant ups , iandc 5kva ups , sup of battery bank , iandc battery bank , supply installation testing and commissioning of sld , supply installation testing and commissioning of 10 line edu , camc for display units, cctv pa display system at tt parking area pachpadra, supply, installation, testing, and commissioning of perimeter non flp fixed camera to record during an alarm/event or in case of network failure, power supply unit / poe, surge protection unit and mounting accessories etc. as per attached technical specifications. material to be supplied with required glands, terminals etc. complete. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of nflp ptz cameras to record during an alarm/event or in case of network failure, power supply unit / poe, surge protection unit and mounting accessories etc. as per attached technical specifications. material to be supplied with required glands, terminals etc. complete. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of indoor dome cameras to record during an alarm/event or in case of network failure, power supply unit / poe, surge protection unit and mounting accessories etc. as per attached technical specifications. material to be supplied with required glands, terminals etc. complete. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of non-flp fixed camera to record during an alarm/event or in case of network failure, power supply unit / poe, surge protection unit and mounting accessories etc. as per attached technical specifications. material to be supplied with required glands, terminals etc. complete. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of cctv server as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of nas device to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., video management software - the software shall be a highly scalable, enterprise level software solution. it must offer a complete video management solution that shall be scalable from 1 to 100 cameras. it shall allow for seamless integration of third party hardware unit and alerts from 3rd party software intelligence systems and intelligent fencing sensors. the system must be capable of working on windows later versions like windows 8, windows 10 and windows server platforms., supply, installation of network 42u of approved make along with required accessories.job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of cctv client hardware with one additional client software as per tender specifications.job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply, installation, testing, and commissioning of 55inch led tv as per tender specifications.job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., industrial grade managed switch-4 port ethernet switch, scope includes supply, installation, testing, and commissioning of 10/100/1000 base-t poe + port based industrial grade managed switch as per datasheet, detailed scope and specifications and stc attached in the tender document. supply must be included with all duties, transportation, pandf charges, freight and insurance charges. e-way bill or road permits shall be arranged by the vendor. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., industrial grade managed switch-12 port ethernet switch, scope includes supply, installation, testing, and commissioning of 10/100/1000 base-t poe + port based industrial grade managed switch as per datasheet, detailed scope and specifications and stc attached in the tender document. supply must be included with all duties, transportation, pandf charges, freight and insurance charges. e-way bill or road permits shall be arranged by the vendor. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., network management/monitoring software shall manage the entire network and shall provide graphical ems/nms interface for easy management, configuration and troubleshooting. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply and fixing of 8 meter height, heavy duty self-supported hot dip galvanized octagonal poles along with foundation per the tender specifications. note_ design vetting from govt college or structural consultant as mentioned in technical specifications is not required. however, design has to be submitted to hpcl. the rates for foundation to be inclusive under this item. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supplying of armored 3 core 4 sq. mm pvc insulated cu conductor with necessary glands, lugs and termination etc., installation, testing and commissioning of cables of size up to 10 sqmm. the scope of job also includes glanding and end termination of all the cables. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply and installation armored cat6 cable with all necessary terminations, complete in all respects. job to be completed as per attached technical specification/ codal provisions/ sound engineering practices and as directed by eic complete., supply and installation cat6 unarmoured cable with all necessary terminations, complete in all respects.job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete., supplying and laying of optical fiber cable, sm, 6 core along with splicing, all complete. job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete., construction and backfilling of cable trench as per tender specifications and approved drawings. job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete., supply and laying of 50mm dia gi pipe for laying of ofc or cat6 cable, supply installation testing and commissioning of perforated type g.i cable trays (14g sheet) of 100mm wide and 50 mm in height with necessary supporting frame and cover for mounting the cable tray on rubble masonry compound wall etc. job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete., laying of free issue cable tray as per eics instruction, supply of following minimum mandatory spares as per tender terms. 1no fixed box-perimeter 1no fixed nflp 1no indoor dome 1no nflp ptz 1no 4 port switch 5nos ofc patch cord job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete, supply construct and testing of earthing electrode conforming to is _3043 _ 2018 inclusive of all materials, supply and fixing of 4 sq. mm copper multistrand frls earthing wire _green _ yellow_, supply, installation and connection of 50mm x6 mm gi earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, all labour and materials as per approved drawings and specifications of this tender. job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete., preparation of all necessary fabrication drawings including bill of materials, supply of structural steel consisting of plates, rolled steel joists, channels, angles, chequered plates, flats in columns, rafters, joists, trusses, gratings of approved design, swing platforms of approved design, insert plates in rcc/brickwork, anchor bolts for steel structure, sleeve pipes, anchor nuts, washers etc., conforming to is_2062/other relevant/applicable codes. the job includes fabrication of steel structures as per drawings/pattern (including preparation of supplementary sketches and detailed bill of materials) supply of bolts, nuts, washers, shims, packs, putty. gas, welding electrodes and all other consumables, as required, cleaning and preparation of all steel surfaces. the primer paint shall be one coat of 65micron inorganic zinc silicate followed by one coat of 100 micron hb mio followed by two coats of acrylic polyurethane each of 40 microns. finishing coat shall be applied one before erection and one coat after erection. total thickness of paint shall be minimum 245microns dft. the scope includes loading, transportation, unloading and delivery at erection site of all fabricated structures, erection, alignment and welding of all structures true to line, level, plumb and dimension, including rectification if any, splicing, site assembly all as per technical specifications and drawings, touch up painting, including supply of paint, where paint is damaged. job to be completed as per attached technical specification/codal provisions/ sound engineering practices and as directed by eic complete. no consideration for wastage for the purpose of payment., fabricate and erection of structure steel using ismb, ismc, isa, flats etc. for various equipments as specified and as directed by e.i.c. approved make_ sail / tata / jindal, comprehensive annual maintenance of complete cctv, pa system and ups for 5 years as per terms and conditions of the contract., non flp type desktop master control station for emergency operation and to provide backup services complete in all respect, erection testing and commissioning of above item, supply of ip-poe based non-flame proof horn speaker as per datasheet, detailed scope and specifications and stc attached in the tender document. supply must be included with all duties, transportation, pandf charges, freight and insurance charges but not limited to. e-way bill or road permits shall be arranged by the vendor, installation and commissioning of ip-poe based non-flp horn speaker supplied as per tender scope. scope also includes glanding, termination, tagging of the power and communication cables. scope includes supply, fabrication of mounting structure and canopy as per the approved drawing, supply of box type ip poe speaker_cone type speaker with necessary mounting accessories, junction boxes, mounting brackets, clamps, nuts etc. suitable for installation inside_outside area complete in all respect., erection, testing and commissioning of box type speaker_cone type speaker in specified area by hpcl as per instruction of site in-charge., supply and fixing of hdpe pipe 50mm dia with all tools, tackles and joints if any required for laying of cable inside the hdpe pipe., supply of 5 kva redundant ups, installation, testing and commissioning of 5kva redundant ups, supplu of smf vrla battery bank suitable for 5kva ups, installation, testing and commissioning of battery bank, supply, installation and testing of single line display for displaying tt no. at loading bay, supply, installation and testing of 10 line display(edu) for tt parking area, comprehensive annual maintenance of complete system of single line display and 10 line display for 5 years as per terms and conditions of the contract.


Tender Value : 0
Due Date : Jul 10, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16121822
live Tender
Location : bardhaman , west bengal
Source : GEM Tenders
live Tender

tender for supply laying testing and connecting xlpe sheathed pvc insulated screened pvc size 3.5 core 240 sqmm complete all as specified and as directed. , supply installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy sound level not more than 75db , m and l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground earth pit not less than 2.25mtr , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in soft loose soil complete all as specified and as directed. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified and as directed. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil complete all as specified and as directed. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches of 230mm , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable complete all as specified and as directed. , s and f galvanised iron pipe 80mm bore dia light grade for protection of ug cable laid in floors road crossing , s and f hdpe dwc double walled corrugated of diameter 90 mm including disconnection and connection of cable , material and labour for manufacturing installation testing and commissioning of factory made and tested cpri approved amf , m and l for surface excavation n.exc not exceeding 30 cm deep and averaging 15cm deep , m and l for hardcore using broken stone or boulders of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick , m and l for cement concrete in foundations filling and mass concrete type d2 1 4 8 , m and l for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping for pole inclduing form work , m and l for excavating in post holes or similar holes each n exc 0.5 cu. m getting out returning filling in and ramming earth , s and f for steel work in tubular trusses cloumn purlin including special shaped washer nut bolt etc. , s and f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick , m and l for preparation of steel surfaces of any description over 10 cm , m and l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 , providing and laying at or near ground level factory made kerb stone of m25 grade , m and l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm , s and f 4pole 630 amp changeover switch with enclosure suitable for 415 v ac 3phase 4 wire , wrecking crow bar or claw bar as per is 706 (q3), supply, laying, testing and connecting xlpe sheathed,pvc insulated screened pvc bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 240 sqmm complete all as specified and as directed., supply, installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy (sound level not more than 75db at a distance of 1 mtr) 14 guage as per guidelines issued by central pollution control board (cpcb ivplus, 4plus), 415 volts, 3 phase, 50 hz supply complete, control panel suitable for giving an output of 250 kva and alternator of suitable capacity and rpm coupled with each other with flexible coupling mounted on anti vibration pads on foundation as recommended by manufacturer. the dg set shall comprise of self starter with batteries, turbocharger, water cooler and comprising all standard fittings, fixtures & all piping etc. as below (a) alternator directly coupled with engine and suitable to produce 415 volts, 3 phase, 4 wire system, 50 hz, 0.8 pf 1500 rpm of capacity 250 kva all as per is 13364 and upto date amendments with h class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball / roller bearing with damper winding in each pole, complete all as specified and directed. (b) engine water cooled diesel engine (cpcb norms iv compliance) developing 105 bhp having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per oem) as per is 10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 rpm industrial type as per bs 649 or is 1601 with ai electronic governor suitable to regulate speed of dg set from no load to full load complete with fuel tank of capacity as per manufacturer s recommendation, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer muffiers etc. for continuous operation and standard accessories, sump pre heaters, cold start kit etc., m&l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground, earth pit not less than 2.25mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the galvanised iron strip of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by provision of 40mm bore gi pipe medium grade and including provision of concrete pit in pcc 1 2 4 type b 1 (using 20mm grade crushed stone aggregate) with 40mm thcik rcc (type b 1) cover reinforced with 8mm dia tmt bar both ways with 12mm dia round bar handle and frame of angle iron 25x25x3mm with lugs 02 nos and 20mm bore gi light grade watering pipe with funnel and wiremesh and filling common salt and charcol and test point with fixing arrangements and including necessary excavation in any type of soil, returning filling in and removing excavated soil to a distance of 50mtr from the site, complete all as shown on electrical plate no 3 of mes ssr part i and directed., excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in soft / loose soil, complete all as specified and as directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed., removing excavated materials (soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil, complete all as specified and as directed., m&l sand cushioning (dry) in trenches for protection of ug cables (below, above and around the ug cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (note for the purpose of payment, punned thickness of sand cushioning only shall be measured and paid)., m&l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable, complete all as specified and as directed., s&f galvanised iron pipe 80mm bore (dia) light grade for protection of ug cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and as directed., s & f hdpe dwc (double walled corrugated) of diameter 90 mm including disconnection and connection of cable near panel/oh for pipe fixing including joints complete all as directed., material and labour for manufacturing, installation testing and commissioning of factory made and tested, cpri approved amf panel for 250 kva dg set, indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 volts, 3 phase 4 wire 50hz ac supply system, conforming to is 5039, ip54 class protection and made of 3mm crca mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated al. bus bar 1000 amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for mccb with suitable capacity of al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments including necessary pcc in 1 2 4 type b1 using 20mm graded stone aggregate for platform of suitable size , prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following acessories incomer1 & 2 (main & dg) (a) busbars 1000a tpn 415volts 3phase 4 wire color coaded aluminium busbars 1 lot (b) mccb 630a fp edo 50ka microprocessor based ( o/c, s/c & e/f) release with motor, closing & shunt, aux. contact 4noplus4nc 2 nos. (c) amf relay (econ) 1 nos. (i) digital ammeter 1 nos. (ii) digital voltmeter 1 nos. (iii) ct 1000/5a cl1 10va 1 nos (iv) phase indication light red 230v ac 1 nos. (v) phase indication light yellow 230v ac 1 nos. (vi) phase indication light blue 230v ac 1 nos. (vii) indication lamp 22mm dia color red 240v ac (on) 2 nos. (viii) indication lamp 22mm dia color green 240v ac (off) 2 nos. (ix) indication lamp 22mm dia color amber 240v ac (trip) 2 nos. etc., m&l for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed., m&l for hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, all as specified and as directed., m&l for cement concrete in foundations, filling and mass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., m&l for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed., s & f for steel work in tubular trusses, cloumn, purlin including special shaped washer, nut, bolt etc. complete using erw or induction butt welded tubes conforming to i.s.1161 1979 grade st.240 complete all as specified., s&f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, m & l for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified, m&l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 of 60 mm thickness, m35 grade with grey cement and pigment all as specified and directed., providing and laying at or near ground level factory made kerb stone of m25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1 3 (1 cement 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed., m&l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% water complete all as specified and directed by engrincharge., s&f 4pole, 630 amp changeover switch with enclosure, suitable for 415 v ac, 3phase, 4wire, 50 hz system, for changeover between main supply and dg set. the switch shall be heavyduty, onload type conforming to is/iec 609473, with silver alloy contacts and adequate breaking capacity. the unit shall be mounted on a sturdy angle iron frame fixed over pcc block with necessary nuts, bolts and support structure. terminals shall be suitable for cable/busbar connection and provision for safe manual operation (or motorised operation, if required) shall be included complete with all accessories, mounting hardware all as specified and directed.


Agency / Dept : indian army
Tender Value : 0
Due Date : Jul 17, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Cable Trench Cover. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Cable Trench Cover sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Cable Trench Cover Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Cable Trench Cover, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Cable Trench Cover Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Cable Trench Cover Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Cable Trench Cover.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Cable Trench Cover depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Cable Trench Cover Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Cable Trench Cover bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Cable Trench Cover. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Cable Trench Cover, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Cable Trench Cover, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Cable Trench Cover?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Cable Trench Cover tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Cable Trench Cover?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Cable Trench Cover, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Cable Trench Cover is declared L1 and is generally awarded the contract